The formulas behind the calculator

Nothing here is proprietary — you can reproduce every number with a pocket calculator.

Room volume (m³) = length × width × ceiling height
Required CADR (m³/h) = room volume (m³) × target air changes per hour
Clean air changes per hour = CADR (m³/h) ÷ room volume (m³)
Time to remove 90% ≈ 2.3 ÷ air changes per hour (hours)  |  99% ≈ 4.6 ÷ ACH
1 CFM = 1.699 m³/h  |  1 m³/h = 0.589 CFM  |  1 ft = 0.3048 m

Assumptions and limits

Which air change target should I choose?

TargetWhen it fits
3 ACHLow-source rooms with good ventilation; background filtration where noise is critical
4–5 ACHGeneral homes and offices. U.S. CDC ventilation guidance suggests aiming for 5 or more air changes per hour of clean air
6 ACHBedrooms of allergy-sensitive people, rooms with pets, rooms next to busy roads
8 ACHOutdoor smoke episodes, dense meeting rooms, fast recovery after cooking
10+ ACHSpecialised settings — design alongside ventilation, not instead of it

A worked example

Bedroom, 4.0 m × 3.5 m, ceiling 2.6 m. Volume = 36.4 m³. At 6 ACH the requirement is 218 m³/h, or 251 m³/h with a 15% margin — about 148 CFM. A purifier rated 250 m³/h at a medium speed would suit; one rated 250 m³/h only at maximum speed probably will not, because it is unlikely to be quiet enough to run overnight. See noise explained.

What to do with the result

  1. Shortlist products whose CADR at a usable fan speed meets your figure.
  2. Check the test method behind the CADR — see CADR explained.
  3. Check the noise level at that speed, then the annual filter cost.
  4. Plan placement so intake and outlet stay clear — see the placement guide.